Instructions manual DS series
7
It is thus important to position the light grid according to the minimum
distance from any reflecting surface.
The minimum distance depends on:
- Device operating distance
- Reflecting surface nature
- Position of the object inside the sensitive area
The minimum distance of the reflecting object has to be:
DS3-SD d > 7 cm
DS3-LD d > 12 cm
If the distance between the receiver and emitter is between 60 and 90
cm
DS3-LD d > 25 cm
If the distance between the receiver and emitter is between 90 and 150
cm
NOTE: These values are based on a mirrored surface sample
with an 80% reflecting index.
Vedere la pagina 9